Eligible Technologies

  • Air Sealing

Building Performance Institute (“BPI”) standards, Energy Star guidelines and/or ASHRAE 62.2-7 2007 Ventilation Standards

Measured by a blower door test before and after improvements are made

  • Duct Sealing

A HERS test is required for duct replacement or repair. A copy of the CF6R Form will be required as part of the Completion Certificate. Total CFM leakage should be less than 6%. Contractors should follow Energy Star guidelines

  • Attic Insulation

Energy Star labeled and R-30 minimum required in open attic

  • Basement Sealing and Insulation

Minimum R-11 wall insulation.

  • Furnace

 Annual Fuel Utilization Efficiency  ≥ 92%

  • Air Conditioning

Seasonal Energy Efficiency Ratio: ≥ 14 SEER

Energy Efficiency Ratio: ≥ 13 EER

  • Appliance

Energy Star Qualified

  • Heat Pumps

Seasonal Energy Efficiency Ratio: ≥ 15 SEER

Energy Efficiency Ratio: ≥ 13 EER

Heating Seasonal Performance Factor:  ≥ 9 HSPF

  • Solar 
  • Doors and Windows
  • Energy Star Qualified

  • Refrigerator Replacement
  • Washer/Dryer
  • Hot Water Heater Replacement

Visit the Glossary of Green Terms for definitions.